Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
Add(Including) alarm to Z-Wave Network1:Make sure the battery is installed well before operating the product. 2:Make sure the alarm is on its final install location, then set the controller into the Add(Inclusion )mode.3:Quickly, triple click the test button, The LED will light up.4:Issued beep, LED off, the alarm being Add (included)to the network successfully.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

The unit is a photoelectric 3V DC smoke and heat alarm. It is operated by 3v AA Alkaline battery. With the photoelectric technology, it is more sensitive in detecting slow smoldering fires which generate light smoke. little heat and may smolder for hours before bursting into flames. This smoke alarm does not contain any radioactive material.The smoke alarm is an intelligent security equipment that can be controlled by the Z-Wave network which has particular frequency. Different countries or areas, the radio frequency of the Z-Wave is different. This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. In the Z-Wave network communications, the smoke alarm can communicate with other devices associated. When the smoke is detected, the sensor will send messages to the main controller, and then the alarm sound. Through the Z-Wave network, the devices associated can response after smoke is detected, For instance , Start fire extinguishing equipment and trigger an alarm, Through the Z-Wave network controller, You will be notified in case of fire.

Reset to factory default Reset will delete all information on the Z-Wave network controller, and restore the alarm to factory default settings. 1: Press and hold the test button , Installing the battery, red LED light, until the LED is off, release the button, LED light up again, press the button again, When hearing a beep, restore factory settings successfully.Note: If this sensor is reset, the information of Z-Wave network in the sensor will be deleted. The sensor will be itself restored to factory default settings. Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Inclusion Add(Including) alarm to Z-Wave Network1:Make sure the battery is installed well before operating the product. 2:Make sure the alarm is on its final install location, then set the controller into the Add(Inclusion )mode.3:Quickly, triple click the test button, The LED will light up.4:Issued beep, LED off, the alarm being Add (included)to the network successfully.
Exclusion 1: Make sure the battery is installed well before operating the product.2: Set the Z-Wave Network controller into Remove(exclusion) mode.3:Quickly, triple click the test button, The LED will light up and alarm enter Remove(Excluding) Mode.4:Wait for the main controller to Remove(exclusion) the alarm.Note: If the alarm is Remove(excluded), then the sensor will be itselfrestored to factory default settings.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 4 Z-Wave Plus Lifeline
2 4 Linkage group 2 is assigned to the devices status - sending BASIC SET control frameto the associated devices having detected the smoke alarm.
3 4 Linkage group 3 reports the detection's status to the associated device. smoke alarm
4 4 Linkage group 4 is assigned to the devices status - sending BASIC SET control frameto the associated devices having detected the heat alarm.
5 4 Linkage group 5 reports the detection's status to the associated device.

Technical Data

Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 255 FW: 1.01:01.01
Z-Wave Version 6.71.00
Certification ID ZC10-17095785
Z-Wave Product Id 0x0266.0x0005.0x0001
Supported Notification Types
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Notification Sensor