This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
This product is a Z-Wave multi-channel device.With dimming and relay two different functions. Built-in S2 security encryption
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
| Group Number | Maximum Nodes | Description |
|---|---|---|
| 1 | 1 | Z-Wave Plus Lifeline |
| 2 | 5 | basic set command |
| 3 | 5 | basic set command |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
LED Indicator Mode for Dimmer Size: 1 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 0 | On when off and off when on |
| 1 | On when on and off when off |
| 2 | Alwaysoff |
| 3 | Alwayson |
Auto Turn-Off Timer for Relay Size: 4 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 0 - 65535 | The countdown time, the Relay off |
Auto Turn-On Timer for Relay Size: 4 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 0 - 65535 | The countdown time, the Relay on |
Restores state after power failure Size: 1 Byte, Default Value: 3
| Setting | Description |
|---|---|
| 0 | dimmer, relay off |
| 1 | dimmer off, relay on |
| 2 | dimmer on, relay off |
| 3 | previous state for dimmer, previous state for relay |
| 4 | previous state for dimmer,relay on |
| 5 | previous state for dimmer,relay off |
| 6 | dimmer on, previous state for relay |
| 7 | dimmer off, previous state for relay |
| 8 | dimmer on, relay on |
Ramp rate (local button only, remote control by command class) Size: 1 Byte, Default Value: 1
| Setting | Description |
|---|---|
| 0 - 99 | from 0x63 to 0x00 or from 0x00 to 0x63 need Required time |
Multilevel minimum value can be set Size: 1 Byte, Default Value: 1
| Setting | Description |
|---|---|
| 0 - 99 | The minimum brightness of a dimmer |
Multilevel maximum value can be set Size: 1 Byte, Default Value: 99
| Setting | Description |
|---|---|
| 0 - 99 | The maximum brightness of a dimmer |
when switch is on or off and quickly press UPPER paddle 2 times, switch turns on to x brightness Size: 1 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 0 | turn on to 99 |
| 1 | turn on to the value relate with parameter 15 |
Double Tap Behavior Size: 1 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 0 | enable double tap to full brightness, single tap to last brightness level or custom value set in parameter 23 |
| 1 | disable double tap to full brightness, single tap to last brightness level or custom value set in parameter 23 |
| 2 | isable double tap to full brightness, single tap always to full brightness |
Enable or Disable local / Z-Wave control for DIMMER Size: 1 Byte, Default Value: 1
| Setting | Description |
|---|---|
| 0 | disable local on/off control |
| 1 | enable local and Z-Wave control (normal operation like now) |
| 2 | disable local and Z-Wave on/off control |
LED Indicator Mode for Relay Size: 1 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 0 | On when off and off when on |
| 1 | On when on and off when off |
| 2 | Always off |
| 3 | Always on |
Enable or Disable local / Z-Wave control for RELAY Size: 1 Byte, Default Value: 1
| Setting | Description |
|---|---|
| 0 | disable local on/off control |
| 1 | enable local and Z-Wave control (normal operation like now) |
| 2 | disable local and Z-Wave on/off control |
Dimmer Speed Setting (only for local press & hold) Size: 1 Byte, Default Value: 4
| Setting | Description |
|---|---|
| 0 - 99 | Time required for local key dimming |
Ramp rate for Z-Wave on/off controlled Size: 1 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 0 | on/off ramp rate for Z-Wave same as manual control (set in Parameter 13) |
| 1 | on/off ramp rate for Z-Wave control set through command class (like now) |
Default brightness level - in this parameter define default brightness level Size: 1 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 0 - 99 | in this parameter define default brightness level |
LED Indicator Color for Dimmer Size: 1 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 0 | White |
| 1 | Blue |
| 2 | Green |
| 3 | Red |
LED Indicator Color for Relay Size: 1 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 0 | White |
| 1 | Blue |
| 2 | Green |
| 3 | Red |
LED Indicator Brightness for Dimmer Size: 1 Byte, Default Value: 1
| Setting | Description |
|---|---|
| 0 | Bright(100%) |
| 1 | Medium(60%) |
| 2 | Low(30%) |
LED Indicator Brightness for Relay Size: 1 Byte, Default Value: 1
| Setting | Description |
|---|---|
| 0 | Bright (100%) |
| 1 | Medium (60%) |
| 2 | Low (30%) |
LED Indicator Mode for Scene Size: 1 Byte, Default Value: 1
| Setting | Description |
|---|---|
| 0 | Enable |
| 1 | Disable |
Auto Turn-Off Timer for Dimmer Size: 4 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 0 - 65535 | The countdown time, the Dimmer Off |
Auto Turn-On Timer for Dimmer Size: 4 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 0 - 65535 | The countdown time, the dimmer on |
| Hardware Platform | ZM5202 |
| Device Type | Light Dimmer Switch |
| Network Operation | Always On Slave |
| Firmware Version | HW: 2 FW: 1.00 |
| Z-Wave Version | 6.82.00 |
| Certification ID | ZC10-20016827 |
| Z-Wave Product Id | 0x0312.0xa000.0xa008 |
| Firmware Updatable | Updatable by Consumer by RF |
| Switch Type | Push Button |
| Color | White |
| Electric Load Type | Dimmable LEDFluorescentIncandescentInductive (e.g. Motor) |
| Security V2 | S2_UNAUTHENTICATED |
| Frequency | XXfrequency |
| Maximum transmission power | XXantenna |