Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Master Roller Blind IO is ready to operate with Z-Wave controllers and configured to be managed by Simon100 IO APP using the HUB plug IO for getting a better user experience. Sending the Blind controller by other window covering devices Up/Down/Stop.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
When the pushbutton is released after a press of (30sec
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
| Group Number | Maximum Nodes | Description |
|---|---|---|
| 1 | 3 | Z-Wave Plus Lifeline |
| 2 | 20 | ctrl.This group is used to add the devices to be controlled by Master Roller blind. Device sends Basic Sets, Multilevel Start or Stop level change when controlling sunblinds, and Manufacturer specific Gets, Configuration Gets and Sets when manual association is being performed over Simon devices. |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Activates the Central LED. Configuration Used by Masters iO in order to identify the devices associated to their Group2 during manual association process. Size: 1 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 0 | Turns Central LED OFF |
| 1 - 255 | Turns Central LED ON |
Sets the Left and Right LEDs to 20% in order to find the device and the touch areas at night. Size: 1 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 0 | Left and Right LEDs OFF |
| 1 - 255 | Left and Right LEDs ON at 20percent |
Locks the local control of associated devices and controller. This configuration does not modifies the control via Z-Wave, where if a Set is received it will retransmitted to all group 2 associated nodes Size: 1 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 0 | Local action enabled |
| 1 - 255 | Local action locked |
Write only parameter used to restore configurations or perform a completely restore default. Size: 1 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 39015 | Factory reset |
| 17170 | Configuration values are restored |
Enables or disables the manual association process. Size: 1 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 0 | Hold press of 10sec to 30sec starts manual association of devices to group 2 |
| 1 - 255 | Hold press of 10sec to 30sec sends a Node Info |
Defines the function performed by the device when keypad is pressed Size: 1 Byte, Default Value: 7
| Setting | Description |
|---|---|
| 0 | short press switches between the last power on and off (depending on the status of the associated control) by sending a Basic Set to 0x00 or 0xFF to the associated nodes. The touch area does not work |
| 1 | Short press activates those associated by sending Basic Set to 0xFF |
| 2 | Short press deactivates those associated by sending Basic Set to 0x00 |
| 3 | Short Press UP always activates those associated with the last power on by sending a Basic Set 0xFF. Short Press DOWN always deactivates those associated by sending a Basic Set to 0x00. |
| 4 | Short Press always turn on the associated nodes by sending a Basic Set to 0xFF. Press from 2sec to 10sec always turns off the associated nodes by sending a Basic Set to 0x00 |
| 6 | Short pressi on UP Area, if controlled device/s already have the value set on Config Param 26, Basic Set 0x00 is sent and UP and DOWN LEDs are turned off; Otherwise Basic Set with value (Param 26) is sent and UP LED light up for 5 sec. After short pressing on DOWN Area, if controlled device/s already have the value set on Config Param 25, Basic Set 0x00 is sent and UP |
| 7 | the key works as described on keypad use and feedbaks |
Write only value that performs a fast blink on Central LED during 5 seconds in order to identify the device when it is installed in a multiple frame Size: 1 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 1 - 255 | Central LED performs a fast blink |
Configuration used to know the device state and last dimming or sunblind position. Size: 2 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 0 - 99 | Load is OFF or sunblind is stopped with diming value or position x |
| 256 - 355 | Load is ON or sunblind is going DOWN with diming value or position x |
| 512 - 611 | Load is ON or sunblind is going UP with diming value or position x |
Value used as DOWN side value when Parameter 20 value is 6Value is SET in hexadecimal format. Size: 1 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 0 - 99 | Value used as DOWN side value when Parameter 20 value is 6 in order to set the loat to the value |
| 255 | Value used as UP side value when Parameter 20 value is 6 in order to Activate Load |
Value used as UP side value when Parameter 20 value is 6Value is SET in hexadecimal format. Size: 1 Byte, Default Value: 255
| Setting | Description |
|---|---|
| 0 - 99 | Value used as UP side value when Parameter 20 value is 6 in order to Set Load to this value |
| 255 | Value used as UP side value when Parameter 20 value is 6 in order to Activate Load |
Locks the major part of Hold press effects in order to avoid undesired Z-Wave changes, associations or restores Default. 0xFF Hold Press from 2sec to 10 sec does not performs a Node info. Hold Press of 10 to 30 does not performs a manual association process. Hold press of 30sec restores configuration except Lock Hold Press, and sends a Node info in order to add or remove from Z-Wave Network. Size: 1 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 0 | Hold press is available |
| 1 - 255 | Hold Press is Locked |
This configuration has only effects when there is only 1 associated node in group 2.Is used to set if Master has to be always informed about the controlled device state or it is consulted when user touchs the keypad. Size: 1 Byte, Default Value: 255
| Setting | Description |
|---|---|
| 0 | Device must receive reports about controlled device state. |
| 1 - 255 | Device consults the device state once keypad detects touch |
Disables the sending of Central Scene Notifications to avoid perform 2 actions at same time (Central Scene action and Group 2 action). Size: 1 Byte, Default Value: 255
| Setting | Description |
|---|---|
| 0 | Device does not sends Central Scene Notifications |
| 1 - 255 | Device sends Central Scene Notifications is no devices are added to group 2 |
| Hardware Platform | ZM5202 |
| Device Type | Wall Controller |
| Network Operation | Always On Slave |
| Firmware Version | HW: 1 FW: 4.24:76.51 |
| Z-Wave Version | 6.51.07 |
| Certification ID | ZC10-18026014 |
| Z-Wave Product Id | 0x0267.0x0005.0x0000 |
| Firmware Updatable | |
| Neutral Wire Required | ok |
| Z-Wave Scene Type | |
| Frequency | XXfrequency |
| Maximum transmission power | XXantenna |