The Z-Wave Plus Siren must be added to a Z-Wave network prior to use. To include the siren in a network both the siren and the network controller must be in inclusion mode at the same time. Refer to the instructions provided by the manufacturer of your specific controller for details on initiating the controllers inclusion mode. 1)Verify that the Z-Wave Plus controller you are using is compatible with the Z-Wave Plus Siren.2)Locate the power outlet desired to be used with the Z-Wave Plus Siren.3)Put your Z-Wave Plus Controller into add (inclusion) mode. 4)Plug in the Z-Wave Siren and verify a single beep sound is heard.5)The LED on the front of the unit will turn off if successful included into a network.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
The Ecolink Z-Wave Plus Siren provides home users with a simple way to keep a location safe and secure.The Ecolink Z-Wave Plus Siren can also be used to audibly notify the user of any Z-Wave state changes.The device is as simple to use as plugging in a wall outlet.The device can create 4 independent tones for different alerts to the user.These could include but are not limited to: Security Alarm, entry/exit, smoke/Fire, temperature and more.The Z-Wave Plus Siren can also be used as a Z-Wave Plus network extension.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
The Z-Wave Plus Siren is automatically factory defaulted when removed from a Z-Wave network. Please use this procedure only when the network primary controller is missing or otherwise inoperable.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
| Group Number | Maximum Nodes | Description |
|---|---|---|
| 1 | 5 | Z-Wave Plus Lifeline |
| Hardware Platform | ZM5202 |
| Device Type | Siren |
| Network Operation | Always On Slave |
| Firmware Version | HW: 255 FW: 1.10 |
| Z-Wave Version | 6.51.06 |
| Certification ID | ZC10-16085156 |
| Z-Wave Product Id | 0x014A.0x0005.0x000A |
| Communications Protocol | Z-Wave Serial API |
| Color | White |
| Switch Type | Rotary Knob |
| Z-Wave Scene Type | Scene |
| Frequency | XXfrequency |
| Maximum transmission power | XXantenna |